Hytrol Catalog

SYSTEMS ACCESSORIES

E24 SINGLE POWERED PIVOT DIVERTER

The Powered Pivot Diverter is designed for use with Models 190- E24 & 190-E24EZ Conveyor. Products are automatically diverted onto adjacent 30˚ spur lines.

MIN. TO DISCHARGE END OF SECTION 4-1/2"

MIN. TO INFEED END OF SECTION 7-1/2"

RH Spur

LH Spur

LH Diverter

RH Diverter

C

DWGNO

C

THISDRAWINGCONTAINSCONFIDENTIAL DESIGNSAND INFORMATIONWHICHARE THEPROPERTYOFHYTROLCONVEYOR COMPANY INC.THISDRAWINGANDTHE INFORMATIONCONTAINEDHEREINMAY NOTBEDISCLOSEDORDUPLICATED IN WHOLEORPART,UTILIZED INANYOTHER WORK,ORUSEDFORMANUFACTUREOF DESIGNSWITHOUTTHEPRIORWRITTEN PERMISSIONOFHYTROLCONVEYOR COMPANY INC. DWGNO Catalog-Int

THISDRAWINGCONTAINSCONFIDENTIAL DESIGNSAND INFORMATIONWHICHARE THEPROPERTYOFHYTROLCONVEYOR COMPANY INC.THISDRAWINGANDTHE INFORMATIONCONTAINEDHEREINMAY NOTBEDISCLOSEDORDUPLICATED IN WHOLEORPART,UTILIZED INANYOTHER WORK,ORUSEDFORMANUFACTUREOF DESIGNSWITHOUTTHEPRIORWRITTEN PERMISSIONOFHYTROLCONVEYOR COMPANY INC.

Catalog-Int

HYTROL

HYTROL

DESIGNEDBY kchurchill kchurchill • STANDARD SPECIFICATIONS ECN DESIGNEDBY CHECKEDBY JONESBORO,ARKANSAS CONVEYORCO., INC. HYTROL DATE DATE MODELS STANDARDTOLERANCES UNLESSOTHERWISESPECIFIED FRACTIONS ±1/64 DECIMALS ±.005 ANGLES ±1° 8/18/2011 DRAWNBY DATE8/19/2011 PAINTCLASS REVISION SPAREPART MFGCLASS kchurchill kchurchill CHECKEDBY DRAWNBY PAINTCLASS JONESBORO,ARKANSAS CONVEYORCO., INC. HYTROL MODELS STANDARDTOLERANCES UNLESSOTHERWISESPECIFIED FRACTIONS ±1/64 DECIMALS ±.005 ANGLES ±1° SPAREPART MFGCLASS

ECN

DATE

8/18/2011

DATE8/19/2011

DATE

REVISION

CAPACITY –75 lbs. maximum package weight.

MOTOR –24 VDC motor, 3 amps per motor, one each Divert Bank.

PACKAGE SIZE –Minimum 4 in. wide x 6 in. long, maximum 26 in. wide x 36 in. long. NOTE: Small packages must not be top heavy. NOTE: Product must be justified to divert side.

MOTOR CONTROLLER – Controls and Protects Motor, one each Divert Bank.

AIR CYLINDER –1 1/4 in. dia. bore x 2 in. stroke, double acting with internal rubber bumpers both ends. C

DIVERTER SPEED – 50-200 FPM set on Motor Controller

DWGNO

THISDRAWINGCONTAINSCONFIDENTIAL DESIGNSAND INFORMATIONWHICHARE THEPROPERTYOFHYTROLCONVEYOR COMPANY INC.THISDRAWINGANDTHE INFORMATIONCONTAINEDHEREINMAY NOTBEDISCLOSEDORDUPLICATED IN WHOLEORPART,UTILIZED INANYOTHER WORK,ORUSEDFORMANUFACTUREOF DESIGNSWITHOUTTHEPRIORWRITTEN PERMISSIONOFHYTROLCONVEYOR COMPANY INC.

Catalog

HYTROL

JONESBORO,ARKANSAS CONVEYORCO., INC. HYTROL

AIR VALVE –Single solenoid 4-way valve with speed controls,1/8 in. NPT valve ports. Requires main- tained electrical signal of 24VDC watt from photo cell, limit switch, etc. (not supplied). Diverter will stay in diverted position until signal is broken. Current consumption is .32 amps holding. AIR REQUIREMENTS –Minimum pressure 60 P.S.I., maximum 125 P.S.I., free air consumption at 60 P.S.I., .032 cu. ft. per cycle. NOTE : To eliminate contaminants in air supply line, a filter-regulator should be installed prior to the air valve (not supplied as standard). DESIGNEDBY CHECKEDBY MODELS STANDARDTOLERANCES UNLESSOTHERWISESPECIFIED FRACTIONS ±1/64 DECIMALS ±.005 ANGLES ±1° DRAWNBY PAINTCLASS SPAREPART MFGCLASS kchurchill kchurchill

DIVERTER MECHANISM –One row of 3 1/8 in. dia. wheels with urethane treads driven by 3/8 in. dia. urethane belts.

ECN

DATE

8/18/

DATE8/19/

DATE

REVISION

MOUNTING –Complete unit bolts to 190-E24 15 in. to 21 in. BR, RH or LH diversion 30˚ spur dis- charge (spur not included). Minimum elevation 14 in. NOTE : O-rings must be opposite discharge side. Widths over 39 in. BR contact factory.

CYCLES –Up to 40 times per minute.

E24 DOUBLE POWERED PIVOT DIVERTER The Double Powered Pivot Diverter is designed for use with Models 190-E24 & 190-E24EZ Accumulating Conveyor. Products are automatically diverted onto adjacent 30˚ spur lines.

MIN. TO DISCHARGE END OF SECTION 7-1/2"

MIN. TO INFEED END OF SECTION 7-1/2"

6

RH Spur

LH Spur

LH Diverter

HYTROL RH Diverter

C

DWGNO

C

DWGNO

THISDRAWINGCONTAINSCONFIDENTIAL DESIGNSAND INFORMATIONWHICHARE THEPROPERTYOFHYTROLCONVEYOR COMPANY INC.THISDRAWINGANDTHE INFORMATIONCONTAINEDHEREINMAY NOTBEDISCLOSEDORDUPLICATED IN WHOLEORPART,UTILIZED INANYOTHER WORK,ORUSEDFORMANUFACTUREOF DESIGNSWITHOUTTHEPRIORWRITTEN PERMISSIONOFHYTROLCONVEYOR COMPANY INC.

THISDRAWINGCONTAINSCONFIDENTIAL DESIGNSAND INFORMATIONWHICHARE THEPROPERTYOFHYTROLCONVEYOR COMPANY INC.THISDRAWINGANDTHE INFORMATIONCONTAINEDHEREINMAY NOTBEDISCLOSEDORDUPLICATED IN WHOLEORPART,UTILIZED INANYOTHER WORK,ORUSEDFORMANUFACTUREOF DESIGNSWITHOUTTHEPRIORWRITTEN PERMISSIONOFHYTROLCONVEYOR COMPANY INC. Catalog

Catalog

HYTROL

• STANDARD SPECIFICATIONS DESIGNEDBY CHECKEDBY JONESBORO,ARKANSAS CONVEYORCO., INC. HYTROL MODELS STANDARDTOLERANCES UNLESSOTHERWISESPECIFIED FRACTIONS ±1/64 DECIMALS ±.005 ANGLES ±1° DRAWNBY PAINTCLASS SPAREPART kchurchill kchurchill ECN DESIGNEDBY CHECKEDBY JONESBORO,ARKANSAS CONVEYORCO., INC. HYTROL DATE DATE MODELS STANDARDTOLERANCES UNLESSOTHERWISESPECIFIED FRACTIONS ±1/64 DECIMALS ±.005 ANGLES ±1° 8/18/2011 DRAWNBY DATE8/18/2011 PAINTCLASS REVISION SPAREPART MFGCLASS kchurchill kchurchill

ECN

DATE

8/18/2011

DATE8/18/2011

DATE

MFGCLASS

REVISION

CAPACITY –75 lbs. maximum package weight.

MOTOR –24 VDC motor, 3 amps per motor, one each Divert Bank.

PACKAGE SIZE –Minimum 4 in. wide x 6 in. long, maximum 26 in. wide x 36 in. long. NOTE: Small packages must not be top heavy. NOTE: Product must be justified to divert side.

MOTOR CONTROLLER – Controls and Protects Motor, one each Divert Bank.

C

DWGNO

THISDRAWINGCONTAINSCONFIDENTIAL DESIGNSAND INFORMATIONWHICHARE THEPROPERTYOFHYTROLCONVEYOR COMPANY INC.THISDRAWINGANDTHE INFORMATIONCONTAINEDHEREINMAY NOTBEDISCLOSEDORDUPLICATED IN WHOLEORPART,UTILIZED INANYOTHER WORK,ORUSEDFORMANUFACTUREOF DESIGNSWITHOUTTHEPRIORWRITTEN PERMISSIONOFHYTROLCONVEYOR COMPANY INC.

AIR CYLINDER –1 1/4 in. dia. bore x 2 in. stroke, double acting with internal rubber bumpers both ends. ECN HYTROL JONESBORO,ARKANSAS CONVEYORCO., INC. HYTROL MODELS

Catalog60inch-Int

kchurchill kchurchill

DESIGNEDBY

DATE

8/18/2011

STANDARDTOLERANCES UNLESSOTHERWISESPECIFIED

DIVERTER SPEED – 50-200 FPM set on Motor Controller

CHECKEDBY DRAWNBY PAINTCLASS

DATE8/18/2011

FRACTIONS ±1/64 DECIMALS ±.005 ANGLES ±1°

DATE

SPAREPART

MFGCLASS

REVISION

AIR VALVE –Single solenoid 4-way valve with speed controls,1/8 in. NPT valve ports. Requires main- tained electrical signal of 24VDC watt from photo cell, limit switch, etc. (not supplied). Diverter will stay in diverted position until signal is broken. Current consumption is .32 amps holding. AIR REQUIREMENTS –Minimum pressure 60 P.S.I., maximum 125 P.S.I., free air consumption at 60 P.S.I., .064 cu. ft. per cycle. NOTE : To eliminate contaminants in air supply line, a filter-regulator should be installed prior to the air valve (not supplied as standard).

DIVERTER MECHANISM –Two rows of 3 1/8 in. dia. wheels with urethane treads driven by 3/8 in. dia. urethane belts.

MOUNTING –Bolts to 190-E24 15 in. to 39 in. BR, RH or LH diversion 30˚ spur discharge (spur not included). Minimum elevation 14 in. NOTE : O-rings must be opposite discharge side. Widths over 39 in. BR contact factory.

CYCLES –Up to 40 times per minute.

CATALOG | 08312018